🔧 Finder Level Monitoring, Pump Control & Surge Protection

Available now at Casadaa Distribution – Your reliable online shop for Finder automation components

💧 Reliable Level Monitoring & Fluid Control

At Casadaa Distribution, we supply a comprehensive range of Finder products for professional liquid level monitoring, pump control, and industrial surge protection. Designed for water treatment, HVAC, industrial automation, and building management systems, these components guarantee precision, safety, and long-term durability.


📡 Liquid Level Sensors & Accessories

Ensure precise level detection in all fluid applications – from tanks and basins to pipes and reservoirs.

Available components:

Part No.Description
072.01.06 / .15Level sensor (standard applications)
072.02.06Probe for chlorinated and saltwater
072.11Floor-level sensor for flooded basement detection
072.31 / 072.41Wired connection level probes
072.500Electrode, 500 mm
072.501Coupling for level probes
072.503Spacer for 3-electrode setups
072.51 / 072.53Electrode holder / 3-pole holder

🔌 Power Supply & Signal Accessories

Part No.Description
07P.000.08 / .12Supply connection cables (pre-terminated)

⚙️ Liquid Level Monitoring Relays

Finder level control relays are used for managing pump operations and detecting minimum/maximum levels in tanks and pipes.

Popular models:

Part No.Description
72.01.8.024 / .240Level control unit, 1 or 2 probes
72.01.9.024Level control, DIN rail mount
72.11.8.024 / .125 / .240Multi-voltage level controllers
72.11.9.024Standard level controller

🔁 Pump Switching & Motor Monitoring Relays

Secure your pump systems from phase loss, overloads, and dry run conditions.

Part No.Description
72.42.0.024 / .230Pump alternation relays for 2-pump installations
70.11.8.230.20221-phase monitoring relay with fault memory
70.31.8.400.20223-phase monitoring relay, adjustable
70.41.8.400.2030 / .20323-phase monitoring incl. neutral detection
70.51.0.240.2032 / N032Universal current monitoring relay (NFC optional)
70.61 / 70.62 series3-phase monitoring, with/without Push-in / Railway type
70.92.0.024 / 230Thermistor protection relays

⚡ Finder Surge Protection Devices (SPDs) – Type 1, 2, and 3

Protect your systems from transient overvoltages in industrial, residential, or photovoltaic environments.

Type 1 + 2 Surge Arresters

  • 7P.02 / 7P.03 / 7P.04 / 7P.05 / 7P.12 / 7P.13 – For single & 3-phase systems, TT / TN-S / TN-C

  • PV-ready Models – DC surge protection for solar installations

  • Variants with remote contact (FM) and voltage tap available

  • Preassembled kits with connection cables (e.g., 7P.04.8.255.Z007C08)

Type 2 SPDs

  • 7P.21 – 7P.27 Series – 1- and 3-phase protection using varistors or spark gaps

  • Models with remote signaling contact (FM) for panel integration

Type 3 SPDs

  • 7P.31 – 7P.37 Series – Final-stage protection near equipment terminals

  • Combination devices with both varistor and spark gap technologies

SPD for Data & Communication Lines

  • 7P.62.9 / 7P.68.9 – Type 2+3 protection for Ethernet and signal lines (e.g. RJ45)


✅ Why Buy Finder at Casadaa Distribution?

  • ✔️ Full Finder portfolio, directly from official distribution

  • 🚀 Fast EU-wide shipping within 24–48 hours

  • 🛒 Secure online ordering with real-time stock levels

  • 📞 Expert support for product selection and system design

  • 📦 B2B services for wholesalers, electricians, and automation engineers


🛍️ Order Finder Monitoring & Protection Devices Now

Explore the best solutions for level control, surge protection, and pump automation at Casadaa Distribution.

Filter
Austrittsfilter, Baugre 2, Auenbereich Finder_7F.03.0.000.2000
Austrittsfilter fr Filterlfter 7F.30, Baugre 2, fr den Auenbereich, Filtermatte nach Klasse G3, Haube aus Kunststoff nach UL94 V-O, lichtgrau, Filtermaterial aus Kunststofffasern, temperaturbestndig bis 100 C., selbstverlschend

€11.61*
Austrittsfilter, Baugre 3, Auenbereich Finder_7F.03.0.000.3000
Austrittsfilter fr Filterlfter 7F.30, Baugre 3, fr den Auenbereich, Filtermatte nach Klasse G3, Haube aus Kunststoff nach UL94 V-O, lichtgrau, Filtermaterial aus Kunststofffasern, temperaturbestndig bis 100 C., selbstverlschend

€28.60*
Austrittsfilter, Baugre 4, Auenbereich Finder_7F.03.0.000.4000
Austrittsfilter fr Filterlfter 7F.30, Baugre 4, fr den Auenbereich, Filtermatte nach Klasse G3, Haube aus Kunststoff nach UL94 V-O, lichtgrau, Filtermaterial aus Kunststofffasern, temperaturbestndig bis 100 C., selbstverlschend

€32.17*
Filterlfter, 100 m3/h, 29 W, Auenbereich Finder_7F.30.8.230.3100
Filterlfter fr Schaltschrank, 100 m3/h, Betriebsspannung 230 V, Betriebsstrom 130 mA, Nennleistung 29 W, Baugre 3, fr den Auenbereich, Montageausschnitt 177 x 177, Schutzklasse IP 54/NEMA Typ 3R, Umgebungstemperatur -30...+55 Grad C

€101.17*
Filterlfter, 24 m3/h, 23 W, Auenbereich Finder_7F.30.8.230.1020
Filterlfter fr Schaltschrank, 24 m3/h, Betriebsspannung 230 V, Betriebsstrom 100 mA, Nennleistung 23 W, Baugre 1, fr den Auenbereich, Montageausschnitt 92 x 92, Schutzklasse IP 54/NEMA Typ 3R, Umgebungstemperatur -30...+55 Grad C

€68.82*
Filterlfter, 250 m3/h, 46 W, Auenbereich Finder_7F.30.8.230.4250
Filterlfter fr Schaltschrank, 250 m3/h, Betriebsspannung 230 V, Betriebsstrom 200 mA, Nennleistung 46 W, Baugre 4, fr den Auenbereich, Montageausschnitt 223 x 223, Schutzklasse IP 54/NEMA Typ 3R, Umgebungstemperatur -30...+55 Grad C

€175.50*
Filterlfter, 400 m3/h, 69 W, Auenbereich Finder_7F.30.8.230.4400
Filterlfter fr Schaltschrank, 400 m3/h, Betriebsspannung 230 V, Betriebsstrom 300 mA, Nennleistung 69 W, Baugre 4, fr den Auenbereich, Montageausschnitt 223 x 223, Schutzklasse IP 54/NEMA Typ 3R, Umgebungstemperatur -30...+55 Grad C

€241.76*
Filterlfter, 55 m3/h, 29 W, Auenbereich Finder_7F.30.8.230.2055
Filterlfter fr Schaltschrank, 55 m3/h, Betriebsspannung 230 V, Betriebsstrom 130 mA, Nennleistung 29 W, Baugre 2, fr den Auenbereich, Montageausschnitt 125 x 125, Schutzklasse IP 54/NEMA Typ 3R, Umgebungstemperatur -30...+55 Grad C

€74.66*